Highest quality standards are achieved through the implementations of latest technology, decades of experience and everlasting moral values , which have helped us to retain our customers as well as multiply them.
DESCRIPTION | |
Moving Iron Instruments are protected from damage or breakage under adverse condition due to its spring loaded jewel & pivot system. These Instruments are free from external magnetic field influences because of magnetic shielding & are 'CE' certified. These instruments have a very efficient oil damping system, which gives almost a deadbeat movement to the pointer, without irksome oscillation. The movement is light yet sturdy and has a large torque to weight ratio which assures long life to instruments. |
|
These indicate true RMS values practically independent of waveform even of high harmonics. The scale is compressed initially. Readability starts from 10 to 15 degree approximately. |
FEATURES | ||
• | Scale | Non-linear. |
• | Suppression | Initial suppression for Voltmeter & End suppression upto 6 times for Ammeter. (on request) |
• | Scale Colour | Special colour scales and marks for different ranges, (on request). |
• | Housing | Engineering plastic. |
• | Terminal Protection | Shrouded terminals to protect from accident, (on request). |
• | Glass | Anti - glare. (on request) |
ELECTRICAL SPECIFICATIONS | ||
• | TYPE | Moving Iron Slide In Scale. |
• | OPERATING VOLTAGE (For Voltmeter) Burden |
15V to 600V. 100V / 110V for PT secondary. 15V to 30V - <100mA, 50V to 100V - < 30mA, 110V to 200V - <15mA, 200V to 600V - <7.5mA. |
• | OPERATING CURRENT (For Ammeter) Burden |
1 A to100A in 72x72, 1A to 200A in 96x96 1A / 5A for CT secondary. 0.25A to 30A - < 1VA, Above 30A - < 1.5 VA. |
• | FREQUENCY | 45 ~ 65Hz. (400Hz. on request). |
• | ACCURACY | Class 1.5 |
• | DIELECTRIC TEST | 2kV RMS or 1 minute. |
• | OVERLOAD CONTINUOUS | 1.2 times |
• | OVERLOAD SHORT TIME | 2 times VN / 10 times IN for 5 seconds. |
• | OPERATING TEMP. | -10°C to 55°C |
• | STORAGE TEMP. | -20°C to 70°C |
• | HUMIDITY | upto 95% RH |
• | CONFORMS TO | I.S. 1248 / I.E.C. 60051 (Part 2). |
MECHANICAL SPECIFICATIONS | ||
MODEL | SMI 72 (Slide in) | SMI 96 (Slide in) |
SIZE ( mm ) | 72 x 72 x 60 | 96 x 96 x 60 |
PANEL CUTOUT ( mm ) | 68 x 68 +0.7 | 92 x 92 +0.8 |
SCALE LENGTH ( Appro. mm ) | 60 | 90 |
WEIGHT ( Appro. gms. ) | <145 For 72 SQ Amps <180 For 72 SQ Volts |
<200 For 96 SQ Amps <230 For 96 SQ Volts |
Note : METERS ARE ALSO AVAILABLE IN 48x48x45 (SMI 48) & 144x144x60 (SMI 144) IN NON SLIDE IN DIAL VERSION. |
MODEL | SMI 48 | SMI 144 |
SIZE (mm) | 48 x 48 x 45 | 144 x 144 x 50 |
PANEL CUTOUT (mm) | 45 x 45 +0.6 | 138 x 138 +1.0 |
SCALE LENGTH (Appro. mm.) | 40 | 145 |
WEIGHT (Appro. gms.) | 100 | 400 |
Ordering information |
1) Type 2) Model 3) Operating Voltage & PTR Voltmeter 4) Operating Current & CTR For Ammeter. |
* To embrace new technologies and methods. * To give unsurpassed products and services to the clients. * To constantly look for improvement and changes.